Three-Phase Diesel Power Station KS 35-3BE
AvailableSpecification
| Voltage, V: | 230/400 |
| Engine brand: | Baudouin |
| Max/Nominal power (400V), kVA: | 35/32 |
Specification
| Voltage, V | 230/400 |
| Max/Nominal power (400V), kVA | 35/32 |
| Max/Nominal power (400V), kW | 28/26 |
| Frequency, Hz | 50 |
| Current (max), A | 51 |
| Outlets | 16A CEE 7/3 (230V), 32A CEE 32/3 (230V), 16A CEE 16/5 (400V), 32A CEE 32/5 (400V), wired 4-core terminal |
| Fuel consumption***, l/h | 3.6 |
| Housing type | soundproof, moisture-resistant, metal, all-weather, vandal-resistant |
| Controller model | Datakom D300 |
| Alternator type | KSA184H |
| Engine type | 4-cylinder diesel with water cooling, 4-stroke |
| Engine brand | Baudouin |
| Engine model | 4M08G8D3/5 |
| Engine speed, U/min | 1500 |
| Engine speed control | ECU-controlled engine speed |
| Preheater | + |
| Output for ATS | + |
| Fuel tank volume, l | 133 |
| Engine cylinder volume, cm3 | 3167 |
| Power output controller | AVR |
| Accumulator (A·h) | 80 |
| Battery charger | + |
| Alternator IP Rating | IP23 |
| Includes | Diesel power station, Operating manual, Product passport, Test protocol, 3×Set of power plugs |
| Net dimensions (LxWxH), mm | 2188×900×1280 |
| Net weight, kg | 955 |
| Gross weight, kg | 955.0 |
| SKU | KS 35-3BE |
| Barcode | 4260405368112 |
Benefits
- Modern and environmentally friendly Baudouin engine (Stage IIIA) with French quality traditions is equipped with an innovative Common Rail electronic fuel injection system controlled by ECU, significantly saves fuel (up to 15%), instantly responds to load changes for stable voltage, low noise and vibration levels, long engine life thanks to optimized fuel combustion.
- Uncompromising reliability and protection in the harshest operating conditions – a soundproof enclosure with IP23 protection made of galvanized steel with powder coating, stainless steel hardware and protective covers for the forklift ensure a long service life of the enclosure without the occurrence of corrosion.
- Multi-level electrical safety – the main ABB circuit breaker with RCD function is complemented by protective residual current circuit breakers for each socket. An emergency stop button is provided.
- Confident starting in cold weather – the coolant preheating system keeps the engine ready to start at low temperatures and increases operational reliability in winter.
- Backup power automation – when connected to an external ATS unit, the Datakom D300 controller ensures automatic starting and stopping of the power station depending on the grid status, guaranteeing uninterrupted backup power supply without user intervention.
Delivery
- Delivery cost is calculated individually. Please contact us for a price estimate.
Shippers:
- DPD (Parcel shipping)
- GLS (Parcel shipping)
- Dachser (Pallet shipping)
- DB Schenker (Pallet shipping)
Shipping Costs:
Delivery cost is calculated individually. Please contact us via email at shop@dimaxgroup.de
Delivery Times:
Unless otherwise specified in the respective offer, delivery within Germany takes place within 1 to 5 days, and for international deliveries within 7 days after the conclusion of the contract. Please note that there is no delivery on Sundays and public holidays.
Transport Damage:
In case of transport damage, you can find more on this page "Behavior in the event of transport
Payment
- We offer a wide range of secure and convenient payment methods, including:
Security and Data Protection:
Your security is our top priority. We use Shopify Payments, one of the most secure payment platforms, to process your transactions. Your payment data is transmitted via an encrypted connection and is never stored on our servers. You can rest assured that your data is fully protected with us.
Shipping and Payment
We ship your order immediately after successful payment, ensuring you receive your products as quickly as possible. Please ensure that payment is made promptly to avoid delays and to have your order in your hands in the shortest possible time.
Refunds:
We want you to be completely satisfied. That's why we offer a 30-day return policy after you receive your order. If a product does not meet your expectations, you will of course receive a full refund. In the case of a refund, it will be processed quickly and easily through your original payment method. Please note that it may take a few days for the refund to be credited depending on the payment provider.To learn more about the easy return process, check this page "Right of Withdrawal".
Features
KS 35-3BE – a three-phase diesel power station with a power output of 35/28 kVA (230/400V), based on a modern economical BAUDOUIN engine (Stage IIIA), which embodies the best practices of French engineering. The power station is equipped with an advanced Common Rail system with electronic fuel injection, ensuring maximum equipment efficiency. Equipped with a Datakom D300 controller with the possibility of connecting an external ATS unit. A soundproof enclosure made of galvanized steel, CEE 230/400V sockets (16A/32A), a preheating system for confident starting in winter and fuel savings of up to 15% make the generator a reliable solution for both industrial and residential backup power supply.
Three-phase diesel power station — designed to provide stable power to three-phase and single-phase consumers and industrial equipment, ensuring even load distribution between phases and reliable system operation.
Possibility of connecting ATS — allows integration with automatic transfer switch systems, ensuring automatic start of the power station and load switching by an external ATS unit without human intervention.
Maximum power 35 kVA (28 KVA) — enables powering production facilities, workshops, agricultural enterprises and other critical infrastructure with high energy consumption.
Four-cylinder Baudouin diesel engine – embodies the best practices of French engineering. With proper and regular maintenance, it guarantees absolute reliability and flawlessly stable operation. Compliance with Stage IIIA means reduced NOx and PM emissions compared to basic requirements, allowing the power station to be used at sites with strict environmental requirements.
Fuel tank 133 L — provides long-term autonomous operation without frequent refueling stops, which is especially important during emergency power outages.
Maximum level of safety — the comprehensive protection system includes monitoring of key operating parameters, a main ABB circuit breaker with RCD function (residual current protection), a residual current protective circuit breaker on each socket, neutral grounding to the frame, a jumper for selecting the TN or IT scheme and an emergency stop button. The electrical safety system includes: protection against current and voltage imbalance, low oil level protection, short-circuit protection, over-power protection, engine over-temperature protection, which increases overall operational reliability.
Soundproof enclosure — reduces noise levels during operation, provides comfortable use near residential or working areas and additionally protects the equipment.
Galvanic coating of the enclosure — increases resistance to corrosion and negative environmental effects, extending the service life of the power station.
Possibility of dry contact control — provides integration with building automation systems, inverters and other external control devices. Upon the customer's request, the Datakom D300 controller can be configured for remote start according to the automation scheme.
Water cooling of the engine — maintains the optimal operating temperature, reduces component wear and increases engine life under prolonged loads.
Pre-start heating — the built-in coolant preheating system automatically maintains the required temperature for safe engine starting, allowing the power station to be started quickly at sub-zero temperatures.
Digital control unit — all operating processes are controlled using the modern multifunctional Datakom D300 digital control unit. The controller displays the main operating parameters, alarm messages and maintenance reminders, and also provides configuration of the power station's start and operation.
Main ABB circuit breaker with RCD function — the main protective switch manufactured by ABB combines the functions of a circuit breaker and a residual current device (RCD) in one housing. Provides instant disconnection in the event of current leakage to the housing, protecting personnel from electric shock even in case of insulation damage.
Stainless steel hinges and locks — all hinges and door locks of the enclosure are made of stainless steel. Increases the resistance of fastening elements to corrosion during long-term outdoor operation or operation in rooms with high humidity.
Fuel level indicator — a built-in “quick” fuel level indicator located near the tank cap allows you to quickly assess the remaining fuel without opening the enclosure and. Reduces the time required to check the power station's readiness for operation during regular maintenance.
LED enclosure lighting — built-in LED lighting inside the enclosure is powered by the power station's starting battery. Provides sufficient illumination for maintenance and troubleshooting under any conditions, including at night or in rooms without external lighting.
Protective covers for forklift openings — the forklift openings are equipped with protective covers that prevent mechanical damage to the enclosure during lifting and transportation. Preserve the integrity of the protective coating at the points of contact with the forks.
Grounding of all enclosure elements — all metal parts of the enclosure are interconnected by a grounding wire, ensuring an equal electrical potential throughout the entire structure. Prevents the accumulation of potential differences between enclosure panels and eliminates the risk of electric shock when touching any part of the power station.
Complete energy flexibility for any equipment
Fully automatic backup power supply
High power for industrial loads
Reliable operation under intensive operating conditions
Stable starting even in cold weather
Increased level of safety and equipment protection
Durability and protection against external influences
Specification
Three-Phase Diesel Power Station KS 35-3BE
| Voltage, V | 230/400 |
| Max/Nominal power (400V), kVA | 35/32 |
| Max/Nominal power (400V), kW | 28/26 |
| Frequency, Hz | 50 |
| Current (max), A | 51 |
| Outlets | 16A CEE 7/3 (230V), 32A CEE 32/3 (230V), 16A CEE 16/5 (400V), 32A CEE 32/5 (400V), wired 4-core terminal |
| Fuel consumption***, l/h | 3.6 |
| Housing type | soundproof, moisture-resistant, metal, all-weather, vandal-resistant |
| Controller model | Datakom D300 |
| Alternator type | KSA184H |
| Engine type | 4-cylinder diesel with water cooling, 4-stroke |
| Engine brand | Baudouin |
| Engine model | 4M08G8D3/5 |
| Engine speed, U/min | 1500 |
| Engine speed control | ECU-controlled engine speed |
| Preheater | + |
| Output for ATS | + |
| Fuel tank volume, l | 133 |
| Engine cylinder volume, cm3 | 3167 |
| Power output controller | AVR |
| Accumulator (A·h) | 80 |
| Battery charger | + |
| Alternator IP Rating | IP23 |
| Includes | Diesel power station, Operating manual, Product passport, Test protocol, 3×Set of power plugs |
| Net dimensions (LxWxH), mm | 2188×900×1280 |
| Net weight, kg | 955 |
| Gross weight, kg | 955.0 |
| SKU | KS 35-3BE |
| Barcode | 4260405368112 |
**In transient modes, the frequency of the generator can change in the short term, that is, during normal operation of the generator, the deviation of the frequency indicator is permissible. Depending on the type of generator, engine and operating mode, the frequency can be 49-54Hz
***Fuel consumption depends on many factors, such as load, fuel quality, season, altitude, technical condition of the generator.